5. Using a crimping tool, crimp the ring terminal to the wire.
6. Slide the ground screw through the ring terminal.
7. Insert the ground screw into the ground-screw opening on the front
panel.
8. Using a ratcheting torque screwdriver, tighten the ground screw and ring
terminal lug to the switch front panel to
0.96 N•m (8.5 lb•in).
9. Attach the other end of the ground wire to a grounded bare-metal
surface, such as a ground bus, or a grounded DIN rail.